From From ultratrace to percentage levels levels
Own bands by element, model, detector, gas and sample mass.
Dedicated analysis of oxygen, nitrogen and hydrogen especially in steels, ferrous and non-ferrous alloys, copper, titanium and metallic powders, from From From ultratrace to percentage levels levels.

The EMGA HORIBA line is especially focused on O, N and H in metals, steels, alloys, copper, titanium and metallic powders. The sample is fused in graphite crucible under inert gas, and the extracted gases are measured by NDIR and/or TCD according to the model.
O, N and H influence properties, processability and reliability. The EMGA family offers configurations for O/N, O/N/H and hydrogen ultratrace.
Own bands by element, model, detector, gas and sample mass.
NDIR and TCD applied to gases formed and conditioned in the analytical flow.
Project oriented to exchange electrodes, dust filter and preventive routines.
Options for crucibles, samples, cleaning and integration with host system.
The sample is fused in graphite crucible to release the gases formed.
Helium or argon transports the extracted gases according to the configuration.
Reagents and columns remove interfering or convert species for each element.
CO/CO2, N2, H2O or H2 are measured according to the model and method.
The family offers different O, N and H configurations; the combined image allows comparison of system dimensions and configurations.



Tracks and times are associated with each model. “Low” and “High” in Pro are selections, not a single continuous track.
Tracks published under the conditions of the manufacturer. The typical cycle is approximately 160 s in the general models and approximately 280 s in the EMGA-21E. The final configuration must validate gas, detector, matrix, mass and optional.
The interface combines extraction curves, results, maintenance and failure recovery in a single window.
It is a family of oxygen, nitrogen and hydrogen analyzers in metals and solids. The sample is fused under inert gas and the extracted gases are measured by NDIR and/or TCD.
The Pro meets selected tracks and is positioned as input solution. Expert expands range and ultratrace performance and offers greater flexibility of options and automation.
Yes. For nitrogen analysis, the specified performance can change with air; the gas must be defined for the method.
The 30E measures O, N and H. The 21E is dedicated to H ultratrace, measures H2 by TCD after column separation and has its own range and cycle.
SENS evaluates model, detector, carrier gas, automation and infrastructure to set up the EMGA platform suitable for your application.