Thermo Scientific™ FlashSmart™

Automated CHNS and oxygen analysis on a single platform.

FlashSmart EA combines combustion for CHNS and pyrolysis for oxygen. In the configuration with two ovens and MVC module, it automatically switches between channels, without manual operator intervention, and performs unattended sequences on solid and liquid samples.

  • CHNS/O on one platform
  • Solid and liquid wide range of sample matrices
  • Automation channel switching without manual intervention
THERMO SCIENTIFIC
Elemental FlashSmart Analyzer in Laboratory Environment
FlashSmart EA Elemental Analyzer

Main differences

Fewer method changeovers. Higher routine throughput.

The CHNS/O configuration brings together two analytical channels and automates the passage between combustion and pyrolysis. The result is a platform prepared to expand the routine without requiring manual reconfiguration at each method change.

Differential CHNS/O

Automatic switch between channels.

With two ovens and the MVC module, FlashSmart switches between CHNS and oxygen without manual operator intervention in changing the analytical channel.

OPERATION

Unattended sequences.

The autosampler and EagerSmart software support routine operation, parameter control and reporting.

FLEXIBILITY

Solid and liquid.

Settings suitable for different elements, sample masses, matrices and analytical objectives.

DETECTION

GC separation with TCD detection.

Integrated analytical flow to separate the produced gases and quantify the elements with reproducibility.

Analytical principle

From sample to result, in an integrated analytical flow.

The sample is converted into gases by combustion or pyrolysis. The components are then separated by gas chromatography and quantified by thermal conductivity detector (TCD). The configuration is selected according to the elements and matrix.

01 Introduction Solid or liquid sample
02 Conversion Combustion or pyrolysis
03 Separation Gas chromatography
04 Detection Quantification by TCD
FlashSmart combustion and pyrolysis analytical flow
Settings for CHNS and oxygen in the same system.

Configurable platform

One analyzer, multiple analytical workflows.

FlashSmart can be prepared for different needs, from routine analysis to special methods and larger mass samples.

CHNS

Dynamic combustion

Simultaneous determination of carbon, hydrogen, nitrogen and sulfur.

O

Pyrolysis

Determination of oxygen with dedicated conversion and chromatographic separation.

NC / TOC

Extended applications

Settings for nitrogen and carbon, total organic carbon and water.

MAS 200R

High throughput

Sample automation for consistent and efficient analytical sequences.

FlashSmart EA isolado em fundo claro

Routine reliability

Designed for unattended operation and reproducible results.

The EAGERSmart software controls analytical parameters, flows, samplers and detectors, as well as generating complete reports. With the MVC module, switching between channels can be automated to increase routine throughput.

Applications

One platform for diverse sample matrices.

Food and feed

Proteins, nitrogen, carbon, hydrogen, sulfur and oxygen in raw materials, foods, beverages and finished products.

Agriculture and fertilizers

Characterization of soils, plants, seeds, fertilizers and inputs for agronomic research and quality control.

Energy and materials

Analysis of fuels, biofuels, coal, polymers, chemicals and materials difficult to homogenize.

Environment and water

Determination of CN, TOC and other elements in environmental samples, water, sediments, filters and related matrices.

Software and throughput

An integrated workflow from method to report.

EagerSmart centralizes instrumental control and treatment of results, while automation modules reduce manual steps and help maintain consistent sequences.

EagerSmart

Control of parameters, flows, samplers, detectors, calibration and reports.

Module MVC

Automated selection of the combustion or pyrolysis route in the CHNS/O configuration.

Automatic sampling

Execution of lots of solid or liquid samples according to the chosen configuration.

Application-oriented configuration

Elements, matrix, sample mass and throughput define the recommended solution.

Frequently Asked Questions

FlashSmart EA — technical information.

Objective information on elemental analysis CHNS/O, automation and platform applications.

Does FlashSmart analyze CHNS and oxygen without manual exchange?

Yes, in the CHNS/O configuration with two ovens and MultiValve Control (MVC) module. The system automatically switches between the combustion channel for CHNS and the pyrolysis channel for oxygen, without manual intervention in channel exchange.

What elements does FlashSmart determine?

Carbon, hydrogen, nitrogen, sulfur and oxygen. The platform also offers specific settings for nitrogen and protein, carbon and nitrogen, total organic carbon and other applications.

Can the equipment operate without continuous monitoring?

Yes. The automatic sampler and the EAGERSmart software allow you to perform analytical sequences and generate reports in unassisted operation.

What types of samples can be analyzed?

The platform supports solid and liquid samples in areas such as food, feed, agriculture, fertilizers, energy, materials, environment and water, according to the selected analytical configuration.

SENS technical consulting

Configuration by sample type

Specify the elements, sample matrices and routine sample volume.

Request evaluation